USER INSTRUCTION & TROUBLESHOOTING of WATER COOLER​

User instruction

  • Don’t use water cooler without proper earthing.
  • Don’t use Multipin for operating water cooler.
  • Don’t run machine without water.
  • Don’t adjust cooling thermostat frequently. Please allow unit to run for 20 minutes between consecutive settings.
  • Don’t block the overflow.
  • Avoid keeping unit in excessively dusty area and heated areas.
  • Don’t use Metal scrubber, harsh soap, iron brush for tank cleaning.
  • Keep 2 ft distance free all round the cooler.
  • Choose the right temperature to avoid overcooling.
  • Keep water cooler in shed and placed in such place where there is free circulation of air.
  • Clean the dirt accumulated on condenser.
  • Water cooler should be switch off when not in use for long hour.
  • Input single phase voltage.

WIRING DIAGRAM

Cooler Capacity Wiring MCB Stabilizer
20 Ltr to 40 Ltr
1 sq mm wiring
6 amp
1.5 KVA
60 Ltr to 100 Ltr
1 sq mm wiring
10 amp
2.0 KVA
100 Ltr to 200 Ltr
2.5 sq mm wiring
15 amp
4.0 KV
300 Ltr
2.5 sq mm wiring
20 amp
5.0 KVA

TROUBLESHOOTING

SYMPTOMS

POSSIBLE CAUSE

SUGGESTED REMEDY

Compressor  does not  run and produces no sound at all.

No power supply

Check Power supply

Fuse blown

Replace the Fuse wire

Faulty Wiring

Call the service personnel.

Compressor tries to start with a humming sound and runs for a short time and shut down.

Low voltage

Check the supply voltage

Capacitor/ relay defective

Call the service Personnel

Unit blows fuse on starting

Compressor defective

Call the service Personnel

Faulty wiring within the unit

Call the service Personnel

Condenser fan motor Noisy

Fan blade may be touching the condenser fin

Call the service Personnel

Condenser  fan motor not working

Open Fan motor connection

Call the service Personnel

Capacitor defective

Replace capacitor

No water flow through water cooler

No water supply

Check water supply

Water filter element may be clogged

Replace filter element

Defective Faucet

Replace faucet

No power supply to purifier

Call the service personnel

Water leaking through Faucet

Improper fixing of Faucet

Call the service Personnel

Water at outlet is warm

Wrong thermostat set point

Check the set point

Water consumption too high

Consume water as per its capacity

Refrigeration not working

Call the service personnel

USER INSTRUCTION & TROUBLESHOOTING of water purifier

The Odipure RO purifier is equipped with many advanced technology which ensure pure, safe and healthy water. It is easy and convenient to install and use.

Important instruction

  • 220 v AC single phase connection not more than 1 meters away from the point of installation of Purifier.
  • Raw water supply with ½” nipple with the maximum distance of 2.5 meter to the point of installation of purifier.
  • Drain for rejected water point should not exceed 2 meter away
  • Ensure the system dimension space and operating space available on the wall.
  • Make sure that the unit is installed in dry and ventilated space.
  • Electrical requirements 220V /5 amp socket with proper earthing to be made available at the point of installation.
  • Avoid sharp bends in the pipe.
  • Avoid installation on false wall, wooden material or any weak stand.
  • For Optimum performance and minimum inlet pressure required, it ensure that raw water supply tank is at least 8- 10 ft above the limit at which the purifier is installed.

Installation Instruction

  • Fix the wall mounting bracket and screws with proper level measurement.
  • Carefully Hang the purifier on the mounting screw.
  • Fix the 3 way ball valve to the ½” port .
  • Connect the 3 way connector  to the raw water supply.
  • Connect one end of white pipe to the ball valve and other end to the filter inlet.
  • Similarly connect one end of blue pipe to rear side connector and leave the other end to drain.
  • Before connecting the power supply, Open the ball valve to start the flow of water into the purifier.

TROUBLESHOOTING

Symptoms

Causes

Suggested Remedy

Change in water taste

Water may be stored for a long time.

Drain the stored water from the storage tank through faucet.

Filters may be damaged.

Call customer care professional.

Check if there is no flow in reject line.

Off the purifier and call customer care professional.

Decrease/ No  Flow of Purified Water

Water supply valve may be closed.

Open the Tap / ball valve.

Ro membrane/ Filters may be clogged or damaged.

Call Customer care Professional.

Less /  no reject water

Check if the reject tube is bent.

Clear the bent in reject tube.

Check if the reject water tube and FR is blocked.

Clean FR & tube. Call customer care Professional.

Pump not working

 No Power supply

Check the Power supply

Transformer burnt out

Replace Transformer/ Call customer care

Pump Bearing Jammed

Replace Pump/ call Customer care

HPS/ LPS  is damaged

Replace LPS/HPS

Bad wire connectivity

Check wire connection

Pump Switches on and off repeatedly

 Low feed pressure

 Faulty LPS

Increase feed water pressure/ Replace LPS.

Bad electrical connection inside pump.

Replace Pump

Pump Is noisy

RO membrane/ Pre/ post filter may be clogged.

Replace Membrane & filters

Pump bearing is worn

Replace Pump

System does not run

High/ low pressure switch is worn

Replace LPS/HPS

Low Feed water pressure

Check feed water pressure

No Power

Check Power source

Solenoid valve is noisy

SV coil is not in place.

Fix the coil in its place

Feed water pressure is too low

Increase feed water pressure

Leakage observed

Tube is not fitted properly

Tube should push properly

Tubing damaged

Replace tubing

“O” rings not grooved properly

O ring should be proper grooved.

Permeate TDS higher than normal

Membrane module not placed correctly

Ensure Correct grooving of membrane

No flow in the reject line

Clean FR

Wrong reject connection

Carry out correct connections

Damage RO module

Replace membranes